Hp Smart Array P410 Raid Controller Driver: Full Version Software
I installed an HP P410 RAID controller in my HP N40L ProLiant MicroServer. My OS is WHS 2011. But I see no way of getting notification of a drive failure other than having to manually open the HP Array Configuration Utility software yourself.
Google this: HP Smart Array SAS/SATA Event Notification Service All the drivers/firmware/software can be found here: The only things you should need aside from Drivers/Firmware are the Event Notification Service and maybe the Array Configuration Utility (ACU). System Insight Manager is an enterprise data center management solution. Huge application and very expensive. Not something you even want to get into. You can look into the System Management Home Page though I'm not sure if that will install on non HP servers.
You could also install the foundation agent: which is an agent piece of the System Insight Management. It would at least send event to the event viewer. However, the Event Notification Server is all you should need. Google this: HP Smart Array SAS/SATA Event Notification Service All the drivers/firmware/software can be found here: The only things you should need aside from Drivers/Firmware are the Event Notification Service and maybe the Array Configuration Utility (ACU). System Insight Manager is an enterprise data center management solution.
Huge application and very expensive. Belly Laughs By Jenny Mccarthy Pdf Printer on this page. Not something you even want to get into. You can look into the System Management Home Page though I'm not sure if that will install on non HP servers. Download Canon Utilities Zoom Browser Ex Download. You could also install the foundation agent: which is an agent piece of the System Insight Management.
It would at least send event to the event viewer. However, the Event Notification Server is all you should need. Click to expand.I was going through the same issue with HP N40L Microserver with WHS2011 and HP P410 - Array was up and running but I couldn't be notified if something went wrong. Elements Of Econometrics Kmenta Pdf Printer here. Eventually I have followed procedure to install PRTG Network Monitor.
This is very clever and versatile soft that monitors your server including raid controller. Operation Flashpoint Resistance Addons Download. Now, whenever there is a status change within an array I receive SMS text massage and e-mail.
In fact I have received text last week when I have updated P410 firmware to 6.0B. Before I was notified when I have added fourth 3TB drive to my array and another one when it has been successfully expanded. Follow what is decried in this thread from the link down below.